描述:
PK PratiKa series female straight sealed sockets Female straight and sealed mobile sockets for cables, suitable for numerous industrial applications. Available in 16 A or 32 A. Snap-on fitting without stripping the wires, fast and reliable. Body with fast opening and closing system. Self-centring cable gland with integral cable clamp. Connection: | plug-in connection ---|--- Protection index: | IP67 / IK08 Frequency: | 50 Hz and 60 Hz Earth contact position: | 6 hrs. ### 标准 NF EN 60309-1 and 2 IEC 309-1 and 2 ### Schneider range
描述:
NG125 circuit breakers NG125 circuit breakers are suitable for high power cut-off requirements, start-up from power panel and entry from modular enclosure head. C curve to control and protect against circuit over-currents (general applications). The magnetic trip units operate between 5 and 10In. Range of differential units and auxiliaries available in catalogue. ### NS compact high power circuit breakers
描述:
Prodis connection busbars The connection busbars ensure correct installation of all "Prodis compatible" systems; DT 40 (1P+N and 3P+N), TL, CT, ITG 40, CM, etc. The busbars can be cut using a saw. Operating voltage: | 230Vac between phase and neutral ---|--- | 400Vac between phases ### 认可 NF USE ### 标准 EN 60947-7 and EN 60439-1 ### 连接母线
描述:
D"clic circuit breakers Range of comb-mountable circuit breakers for controlling and protecting single phase circuits downstream of the connection circuit breaker . Can be used in all installations supplied by the public network in the "blue tariff". The magnetic trip units work between 5 and 10In. Quick closure. Technical specifications --- Type: | single pole + neutral Operating voltage: | 230Vac Breaking capacity: | 3000A (NFC 61410 and EN 60898) Cable connection: | 16mm2 max. ### 标准 NFC and EN 60898 ### Merlin Gerin 配电板和配件
描述:
CT"clic contactors CT contactors are designed to remotely control single-phase circuits. Compatible with comb-mountable or plug-in circuit breakers. Connectors ensure a fast, safe electrical connection to the line protection circuit breaker. Quick connection can be removed for fast wiring. Red voltage indicator. Stock no. | rating (A) | contact | pitch width | consumption, start-up | consumption, maintenance ---|---|---|---|---|--- 145-386 | 20 A | 2 N/O | 2 | 15 VA | 3.8 VA 145-364 | 20 A | 2 N/O | 2 | 15 VA | 3.8 VA 144-440 | 20 A | 2 N/C | 2 | 15 VA | 3.8 VA 144-434 | 40 A | 2 N/O | 4 | 34 VA | 4.6 VA ### 标准 NF EN 61095 ### Schneider Modular Contactors
描述:
BP"clic push-buttons Push-buttons for mounting onto DIN rails. For pulse control. 2- or single-pole versions available. 标准 EN 60669-1 and EN 60947-5-1 断路器和差动开关 - Legrand
描述:
Distri"clic XE splitters Splitters for XE plug-in technology. A connector combined with a splitter supplies two rows. stock no. 145-279. Rated operating current: 63 A @ 40 °C. Rated insulating voltage: 250 Vac Mounting on support provided at the back of the symmetrical rail on Opale and Pragma evolution enclosures. ### Merlin Gerin 配电板和配件
描述:
Accessories for NG125 Circuit Breakers Range of electrical accessories including trip units and contacts, as well as accessories for connection, comb busbars, tooth ends and 100A flexible connections. MN voltage release trip unit. MNs (0.5 s) undervoltage trip unit. MNx trip unit for opening BP. MX + OF shunt trip. Auxiliary contact O/C + O/C Auxiliary contact O/C + SD ### NS compact high power circuit breakers